CASE STUDY

Hazleton Pumps Logo

Rössing Uranium, Namibia

Challenge

  • The project required heavy-duty Verticle Spindle slurry pumps, to be installed on pontoons, capable of operating with corrosive slurry of a PH below 4
  • Ambient temperatures up to 43 degrees celcius in Namibia’s desert climate

Solution

  • Pump cast and manufactured of CD4MCu Duplex stainless steel to withstand corrosion
  • 185kW and 250kW motors capable of handling specific gravity
  • Reasonable cost of ownership and long-term value of ownership
  • Minimum down-time: Reliability and durability
  • Design allows pumps ability to run dry
  • Double discharge volute design provides balanced radial loads to increase bearing life